The EOC Particle and Dust Sensor Modules are complete systems with the following benefits:

  1. Simultaneous Output from all 3 ranges, PM1.0, PM2.5, PM10
  2. API (Auto Particle Identification) Technology Constant power laser diode
  3. Constant RPM speed for fan
  4. Small particle correction technology
  5. Working temperature range as broad as -40~85℃ (Outdoor System)
  6. Longer lifetime with laser diode MTTF>110,000 hours
  7. Anti-Dust structure design to prevent dust accumulation (Outdoor System)
ApplicationModel NumberMeasurement
Range
Output ChannelAccuracyPower
Requirements
Operating TemperatureStorage TemperatureCommunication ProtocolCommentsMOQ
LED Dust SensorEOC-PC-2105-M0~1000μg/m³PM1.0+PM2.5+PM10PM1.0&PM2.5:
0 ~35μg/m³, ±5μg/m³
35μg/m³~500μg/m³, ±15% of reading
PM10:
0 ~100μg/m³, ±30μg/m³
101 ~500μg/m³, ±30% of reading
<100 mA
DC 5V±0.1V
-10°C ~ 60°C-40°C ~ 80°CUART,I2CReal-time output PM1.0, PM2.5, PM10 in μg/m3 available
Air inlet and outlet on opposite side
1000
Laser Dust SensorEOC-PC-2008M-M0~1000μg/m³PM1.0+PM2.5+PM10 PM1.0&PM2.5:
0 ~35μg/m³, ±5μg/m³
35μg/m³~500μg/m³, ±15% of reading
PM10:
0 ~100μg/m³, ±30μg/m³
101 ~500μg/m³, ±30% of reading
<100 mA
DC 5V±0.1V
-10°C ~ 60°C -40°C ~ 80°CUART,I2C Real-time output PM1.0, PM2.5, PM10 in μg/m3 available
Air inlet and outlet at the same side
Connect way is by cable
1000
Laser Dust SensorEOC-PC-2008 0~5000μg/m³PM1.0+PM2.5+PM10 PM2.5/PM1.0:
0~100μg/m³, ±10μg/m³
101~500μg/m³, ±10% reading
PM10:
0~100μg/m³, ±25μg/m³
101~500μg/m³, ±25% reading
<100 mA
DC 5V±0.1V
-10°C ~ 60°C -40°C ~ 80°CUART,I2C Real-time output PM1.0, PM2.5, PM10 in μg/m3 available
Air inlet and outlet at the same side
Connect way is without cable, DIP to PCB board
1000
Laser Dust SensorEOC-PC-2012 0~5000μg/m³PM1.0+PM2.5+PM10 PM2.5/PM1.0:
0~100μg/m³, ±10μg/m³
101~500μg/m³, ±10% reading
PM10:
0~100μg/m³, ±25μg/m³
101~500μg/m³, ±25% reading
<100 mA
DC 5V±0.1V
-10°C ~ 60°C -40°C ~ 80°CUART,I2C Smallest Size1000
Laser Dust SensorEOC-PC-20090~5000μg/m³PM1.0+PM2.5+PM10 PM2.5/PM1.0
<50 μg/m³ : 5 μg/m³
50 μg/m³ ~100 μg/m³ : 10 μg/m³
100 μg/m³~ 300 μg/m³ : 15% of reading
0~100μg/m³: +/-25 μg/m³
100μg/m³~300μg/m³: +/ 25 of reading
Condition: 25±2℃,50±10%RH
<100 mA
DC 5V±0.1V
-20°C ~ 60°C -40°C ~ 80°CUART,I2C API technology
Better for PM10 measurement
Anti-dust deposition structure
Higher working temperature range
1000
ApplicationModel NumberMeasurement
Range
Output ChannelAccuracyPower
Requirements
Operating TemperatureStorage TemperatureCommunication ProtocolCommentsMOQ
Exterior
Applications
EOC-PC-3006T0~30,000μg/m³
(extented to 10mg/m³)
PM1.0+PM2.5+PM10PM1.0/PM2.5:
<35μg/m³: ±5μg/m³
35~100μg/m³: ±10%g
101~1000μg/m³: ±10% reading
PM10:
0~100μg/m³, ±15μg/m³
101 ~ 1000μg/m³, ±15% reading
<250 mA
DC 5V±0.1V
-30°C ~ 70°C -40°C ~ 85°CUART,I2C Outdoor particle sensor5
Clean Room &
Exterior
Applications
EOC-PC-50000~10,000,000 pcs/L (1pcs/L=28.3pcs/cf)>0.3um, >0.5um, >1.0um, >2.5um, >5.0um, >10um70%@0.3μm; 99%@≥0.5μm<250 mA
DC 5V±0.1V
-30°C ~ 70°C-40°C ~ 85°CUART,I2C Particle counter for cleanroom5